Multi-compartment T2 relaxometry using a spatially constrained multi-Gaussian model.
Publication Type | Academic Article |
Authors | Raj A, Pandya S, Shen X, LoCastro E, Nguyen T, Gauthier S |
Journal | PLoS One |
Volume | 9 |
Issue | 6 |
Pagination | e98391 |
Date Published | 06/04/2014 |
ISSN | 1932-6203 |
Keywords | Brain, Image Interpretation, Computer-Assisted, Magnetic Resonance Imaging, Myelin Sheath, White Matter |
Abstract | The brain's myelin content can be mapped by T2-relaxometry, which resolves multiple differentially relaxing T2 pools from multi-echo MRI. Unfortunately, the conventional fitting procedure is a hard and numerically ill-posed problem. Consequently, the T2 distributions and myelin maps become very sensitive to noise and are frequently difficult to interpret diagnostically. Although regularization can improve stability, it is generally not adequate, particularly at relatively low signal to noise ratio (SNR) of around 100-200. The purpose of this study was to obtain a fitting algorithm which is able to overcome these difficulties and generate usable myelin maps from noisy acquisitions in a realistic scan time. To this end, we restrict the T2 distribution to only 3 distinct resolvable tissue compartments, modeled as Gaussians: myelin water, intra/extra-cellular water and a slow relaxing cerebrospinal fluid compartment. We also impose spatial smoothness expectation that volume fractions and T2 relaxation times of tissue compartments change smoothly within coherent brain regions. The method greatly improves robustness to noise, reduces spatial variations, improves definition of white matter fibers, and enhances detection of demyelinating lesions. Due to efficient design, the additional spatial aspect does not cause an increase in processing time. The proposed method was applied to fast spiral acquisitions on which conventional fitting gives uninterpretable results. While these fast acquisitions suffer from noise and inhomogeneity artifacts, our preliminary results indicate the potential of spatially constrained 3-pool T2 relaxometry. |
DOI | 10.1371/journal.pone.0098391 |
PubMed ID | 24896833 |
PubMed Central ID | PMC4045663 |